Parker PDHX-E Series User Manual page 83

Table of Contents

Advertisement

Vs
LMT+
LMT-
HOME
STOP
AUX-IN
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
Vs GND
Programmable Output
You can program each output, or configure it, to perform to a particular function. There are 6
user definable outputs which can be programmed as either NPN or PNP open collector
outputs.
To allocate an output to a particular function use the OUT command. The user definable
outputs are labelled OUT1 to OUT6 on the front panel. All output functions have been
assigned a letter, refer to the OUT command in the software section.
To program an output to perform a function, use the OUT command followed by the output
number and the corresponding function letter.
For example
The choice of NPN or PNP output can be programmed using the OCON command.
To view the current status of the user definable output type 1OUT. All user definable outputs
will be displayed.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
+24V DC
STOP
PLC
Figure 7-6 Input Example
1OUT3T
+24V DC
PNP
PNP
KILL
0V
Set output 3 as in position.
PNP