Pre-installation Test
This section provides procedures to help you to connect up your PDHX-E drive system for a
pre-installation test. Please note the pre-installation test allows you to become familiar with
the operation of the drive prior to permanent installation, it should only be set up and used by
competent personnel familiar with installation of motion control equipment.
Figure 2-2 illustrates the pre-installation test configuration for systems operating from a 230V
mains supply. Please note the following:
• The motor should be securely clamped to the test bench before any power is supplied.
Minimum RS232 Connections
You will need to make a connection between a terminal and the drive. The simplest
connection that can be made is using a RS232 communicatins link as detailed below.
Drive RS232/RS485 9-way
D-type Connector
3 0V
4 RxA
5 TxA
Note: The RS232 connections need to be made using a braided screen cable with metal
back shells on the D-type connectors to maintain EMC compatibility.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Computer 9-way D-type
5
3
2
Table 2-2. Minimum RS232 Connections
Computer 25-way D-type
7
3
2