Parker PDHX-E Series User Manual page 33

Table of Contents

Advertisement

Selftest Switch1
The selftest switch is used to check the operation of the drive. Set to the ON position to
cause the motor to rotate at slow speed. The default setting of selftest is OFF i.e. not
selected.
Standby Switch 2
Switch 2 determines the level of standby current. With switch 2 ON, the current will reduce
by 50% at standby. With switch 2 OFF, current will be reduced to 80% of the programmed
value at standby.
Step Resolution Switch 4, 5
DIP Switches 4 and 5 determine the step resolution of the drive, as defined in Table 3-11.
Note: cycle the power for switch settings to take effect.
Peak Current Setting Switch 6, 7, 8
DIP Switches 6, 7 and 8 determine the peak current setting of the drive, as defined in
Table 3-12.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
SWITCH
RESOLUTION
SETTINGS
IN
STEPS/REV
4
5
ON
ON
400
ON
OFF
1000
OFF
ON
2000
OFF
OFF
4000
Table 3-11. Step Resolution Settings
SWITCH SETTINGS
6
7
8
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
Table 3-12. Peak Current Settings
PEAK
CURRENT
5.0A
4.6A
4.3A
3.9A
3.6A
3.2A
2.9A
2.5A

Advertisement