Sprayer Fault Codes - Toro 34230 Operator's Manual

Stand-on e-spreader/sprayer
Table of Contents

Advertisement

Spreader Fault Code Table (cont'd.)
Motor Wire !05
The motor wire fault code !05 displays if the sprayer controller
cannot sense the load circuits (O
sprayer and information display and the motor.
Fault code !05 displays in the sprayer and information display.
The LED status light illuminates red.
Check that pin 6 (M
OTOR
seated and locked in the controller connector.
Motor Open !06
The motor open fault code !06 displays if the spreader controller
cannot sense the motor signal circuit (M
Fault code !06 displays in the spreader and information
display.
The LED status light illuminates red.

Sprayer Fault Codes

Sprayer Fault Code Table
Voltage
The voltage fault code displays if the key-run voltage is less than
12.5 V or greater than 16 V.
The voltage fault code flashes in the sprayer and information
display.
The LED status light illuminates red.
The agitation motor shuts off.
1 or O
2) between the
UT
UT
O
1) and pin 8 (M
O
UT
OTOR
I
).
OTOR
N
2) are
UT
76
1. Fault code !05 (motor wire)
1. Fault code !06 (motor open)
Voltage fault code