IBM ServeRAID-4 Ultra160 Series User Reference page 161

Scsi controller
Hide thumbs Also See for ServeRAID-4 Ultra160 Series:
Table of Contents

Advertisement

BCS
ECS
Explanation
01
08
No configuration was found in drives, or the
Online/Rebuild drives are not responding.
01
18
No configuration was found in drives, or the
Online/Rebuild and Hot-Spare/Standby
Hot-Spare drives are not responding.
01
28
No configuration was found in drives, or the
Online/Rebuild and Ready/Standby drives are
not responding.
01
38
No configuration was found in drives, or the
Online/Rebuild, Hot-Spare/Standby Hot-Spare,
and Ready/Standby drives are not responding.
01
48
No configuration was found in drives, or the
Online/Rebuild drives are not responding and
unidentified drives were found.
01
58
No configuration was found in drives, or the
Online/Rebuild and Hot-Spare/Standby
Hot-Spare drives are not responding and
unidentified drives were found.
01
68
No configuration was found in drives, or the
Online/Rebuild and Ready/Standby drives are
not responding and unidentified drives were
found.
01
78
No configuration was found in drives, or the
Online/Rebuild, Hot-Spare/Standby Hot-Spare,
and Ready/Standby drives are not responding
and unidentified drives were found.
Action
To correct the problem:
1. If the controller is connected to an enclosure,
check to make sure that the enclosure is On. If
the enclosure is not On, turn on the power and
press F4 to retry.
2. Check to make sure that all the physical drives
are present. If any drives are missing, replace
the drives and press F4 to retry.
3. Make sure that all the physical drives are
connected to the controller correctly. If any
drives are unconnected, connect the drives and
press F4 to retry.
4. If all the physical drives are present and
connected correctly, one or more of the drives
might be faulty. Identify and replace the faulty
drives; then, press F5 to accept the changes.
5. If you have intentionally switched physical
drives that are connected to this controller,
press F7 to import the configuration from the
drives and account for the drive rearrangement.
To exit without making changes, press F10.