Explanation
Recoverable
The configuration data stored in
configuration
NVRAM does not match the
error
configuration data stored in the
EEPROM.
Unrecoverable
The configuration data stored in
configuration
NVRAM does not match the
error
configuration data stored in the
EEPROM.
140
®
IBM
User's Reference: ServeRAID
Action
F7
1. Press Ctrl+I to access the ServeRAID
Mini-Configuration menu. (See "Chapter 7. Using the
ServeRAID Mini-Configuration program" on page 53 for
more information.)
2. Select Advanced Functions from the Main Menu.
3. Then, select Copy the Configuration from Drives to
the Controller. (See "Using the advanced
configuration functions" on page 54 for more
information.)
1. Press Ctrl+I to access the ServeRAID
Mini-Configuration menu. (See "Chapter 7. Using the
ServeRAID Mini-Configuration program" on page 53 for
more information.)
2. Select Advanced Functions from the Main Menu.
Attention:
all online drives in an array to ready. You must import
the configuration from the drives or diskette.
Otherwise, you must create a new array and logical
drives. When you create new logical drives, they are
automatically initialized. All data is lost and you must
re-install the operating system and data.
3. Select Restore to the Factory Default Settings. (See
"Using the advanced configuration functions" on
page 54 for more information.)
-4 Ultra160 SCSI Controller
Import configuration information from drive. Press
this key to restart the server. Press this key to
import the configuration information from the drive
and to update the configuration information for the
ServeRAID controller. This choice is useful when
you replace the ServeRAID controller in an
existing ServeRAID subsystem.
You also might press F7 if you replace a whole
set of drives with drives that were configured in
another server with a ServeRAID controller.
Note: When you install drives in a server that
has no logical drives defined, the F7 choice will
not appear. The ServeRAID controller does not
contain any logical drives in its factory
configuration. Therefore, F7 will not appear. In
this case, do the following:
1. Restart the server and press Ctrl+I to enter
the Mini-Configuration program. (See
"Chapter 7. Using the ServeRAID
Mini-Configuration program" on page 53 for
more information.)
2. Select Advanced Functions.
3. Select Copy the Configuration from Drives
to the Controller and follow the instructions
on the screen.
Restoring to factory default settings sets