21 SCAN
21.1.3 Operations when Scan Cannot
Resume
During the scan, the selected CH/GID appears and "
icon blinks on the display if the transceiver is manually
changed to a zone that does not meet the requirements
to resume the scan. In this case, the transceiver does not
resume scanning.
The transceiver transmits using the Revert CH/GID when
the PTT switch is pressed while the "
The transceiver returns to the selected CH/GID if the
Dwell Time elapses after the transceiver finishes
transmitting. However, the transceiver does not resume
scanning.
21.1.4 Operation after Manually
Changing the Zone-CH/GID
during the Scan
The transceiver activates in the following way if the Zone-
CH/GID is changed during the scan.
Table 21-1 Operation after Changing the Zone-CH/GID
Display
The transceiver stops scanning on the selected CH/
GID.
Scan
The transceiver resumes scanning after the Dwell
Time elapses.
The transceiver pauses scanning on the selected
Revert
CH/GID when the Revert CH/GID is different from
CH/GID
the selected CH/GID.
The transceiver activates in the following way if the Home
CH/GID key is pressed during the scan.
Table 21-2 Operation after Pressing the
Home CH/GID Key
Scan
Type
The transceiver stops scanning on the Home CH/
GID. The transceiver checks and looks back for
signals during the Priority Scan.
When the Home CH/GID key is pressed again, the
Scan
transceiver returns to the selected CH/GID and
resumes scanning.
The transceiver emits the Scan Stop Tone every 5
seconds while the transceiver pauses scanning.
The transceiver jumps to the Home CH/GID of the
Single
selected Zone.
Scan
In this case, the selected CH/GID is not changed.
The transceiver jumps to the Home CH/GID of the
Multi
Revert Zone.
Scan
In this case, the selected CH/GID is not changed.
106
Index
Contents
" icon is blinking.
Operation
Operation
The transceiver activates in the following way if one of the
Direct CH/GID 1 to Direct CH/GID 4 keys is pressed
during the scan.
The transceiver stops scanning on the Direct CH/GID
"
1 to Direct CH/GID 4.
If no signal is present, the transceiver resumes
scanning from the current Direct CH/GID after the Key
Dwell Time elapses. The transceiver activates in the
same way even if the transceiver is executing the
Priority Scan.
If a Conventional Group channel is configured for
Direct CH/GID nn and "Selected" is selected from the
Priority dropdown list, Direct CH/GID nn is configured
for the Priority Channel.
If "Selected" is selected from the Revert CH/GID
dropdown list, Direct CH/GID nn is configured for the
Revert CH/GID.
21.1.5 Operations when Manually
Changing the Zone-CH/GID
while Scan Pauses to Receive a
Call
The transceiver activates in the following way if the Zone-
CH/GID is manually changed during the scan to receive a
call.
The transceiver pauses scanning on the selected CH/
GID when the selected CH/GID is different from the
CH/GID on which the transceiver stops scanning.
21.1.6 Transceiver Operation during
the Scan
Transceiver operation during the scan varies between
Conventional Group and Trunking Systems.
Conventional Group
The transceiver activates as configured in the Zone
Edit window (Conventional Group) > Audio Control
dropdown list.
Confidential
FUNC (K)/Ver. 1.01

Hide quick links: