Application Indicator Function; Indication By Application Indicator Input - Panasonic SF4D-TM1 User Manual

Communication module for the sf4d series
Hide thumbs Also See for SF4D-TM1:
Table of Contents

Advertisement

Functions

5-7 Application Indicator Function

This function allows the upper application indicator and lower application indicator of the light
curtain to be used in application mode.
Set DIP switch 3 on the light curtain receiver to ON, and switch from beam adjustment mode to
application mode.
Indication by the light curtain's application indicator input 1 wire / 2 wire and indication in re-
sponse to states of the light curtain are possible.
The factory set color of the application indicator input 1 wire is gray, and the factory set color of
the application indicator input 2 wire is gray / black. For the lead wire color when the input / out-
put wire setting is changed, refer to "5-2 Input / output specifications".
When multiple light curtain units are connected in series, beam adjustment mode and applica-
tion mode can be used together.
Mixed application modes can also be used.

5-7-1 Indication by application indicator input

You can select application indicator ON / OFF with the wiring of the application indicator input 1
wire / 2 wire of the light curtain.
The software tool can be used to set changes to the indication color and Blinking / OFF.
5-7-1-1 Application indicator input 1 / 2 wire
The cable and input / output specification determine whether or not the light curtain's application
indicator input 1 wire / 2 wire is incorporated. When the light curtain's application indicator input
1 wire / 2 wire is "incorporated", indication by application indicator input 1 wire / 2 wire is pos-
sible.
In the case of line synchronization, indication by the light curtain's application indicator input 1
wire / 2 wire takes place on the emitter and receiver.
In the case of optical synchronization, indication takes place on an emitter or receiver equipped
with the light curtain's application indicator input 1 wire / 2 wire. In the case of optical synchroni-
zation, settings by the software tool are written to an emitter or receiver equipped with the light
curtain's application indicator input 1 wire / 2 wire.
Cable used
Standard specification
Parallel interference prevention specification
12-core cable
Optical synchronization / standard specification
Optical synchronization / muting specification / PNP output Optical synchronization Incorporated (Note 2)
Optical synchronization / muting specification / NPN output Optical synchronization Incorporated (Note 2)
8-core cable
Standard specification
Optical synchronization / standard specification
Optical synchronization / application indicator-
5-core cable
based specification / PNP output
Optical synchronization / application indicator-
based specification / NPN output
Notes: 1) The light curtain emitter is only equipped with application indicator input 1.
2) In the case of optical synchronization, indication only takes place on the light curtain emitter.
3) The light curtain emitter and receiver are each equipped with application indicator input 1.
82
Input / output specification (cable function)
Synchronization
method
Line synchronization
Line synchronization Incorporated (Note 1)
Optical synchronization Incorporated (Note 2)
Line synchronization
Optical synchronization
Optical synchronization Incorporated (Note 3)
Optical synchronization Incorporated (Note 3)
© Panasonic Industrial Devices SUNX Co., Ltd. 2020
Application indicator
input 1 wire / 2 wire
Incorporated
Not incorporated
Not incorporated

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sf4d series

Table of Contents