Panasonic SF4D-TM1 User Manual page 61

Communication module for the sf4d series
Hide thumbs Also See for SF4D-TM1:
Table of Contents

Advertisement

● Wiring example: Line synchronization / parallel interference prevention specification
(12-core cable)
<Using PNP output>
Gray cable
Gray cable
(with black line)
Gray cable
Gray cable
(with black line)
© Panasonic Industrial Devices SUNX Co., Ltd. 2020
(Gray) Application indicator input 1
(Gray / Black) Parallel interference prevention input
(Red / White) Muting auxiliary output
(Yellow) Override input
(Brown) + V
(Pale purple) Interlock setting input
(Pink) Test / Reset input
(Red) Auxiliary output 1
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
(Orange) Synchronization +
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
(Orange) Synchronization +
(Pale purple) External device monitor input
(Brown) + V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
(Pink) Muting input A
(Yellow) Muting input B
(Gray) not used
(Red) Parallel interference prevention output
(Gray / Black) Parallel interference prevention input
(Gray) Application indicator input 1
(Red / White) Muting auxiliary output
(Yellow) Override input
(Brown) + V
(Pale purple) Interlock setting input
(Pink) Test / Reset input
(Red) Auxiliary output 1
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
(Orange) Synchronization +
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
(Orange) Synchronization +
(Pale purple) External device monitor input
(Brown) + V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Pale blue) Output polarity setting / Lockout release input
(Blue) 0V
(Pink) Muting input A
(Yellow) Muting input B
(Red) Parallel interference prevention output
(Gray) not used
Functions
*S1
+
Load
K1
K2
K1
K2
*Symbols
Switch S1
Vs to Vs-2.5V (sink current 5mA or less):
Emission halt (Note 1), Open: Emission
K1, K2:
External device (forcible guide relay
or magnetic conductor), etc.
Note 1: Vs is the supply voltage.
*S1
+
Load
K1
K2
K1
K2
24V DC
+20
%
-
-30
24V DC
+20
%
-
-30
61