Procedures for Operation
3-2-2 Copy functions: WRITE function
Procedure
1
2
3
4
5
6
7
8
Note: Data copied by the copy function may disappear due to external causes. After copying, check the operation
of the light curtain before use.
24
State
Connect the connection cable of the device to the connector inside
the light curtain.
All indicators light up for about 1 second.
Indicators other than the power indicator (green) and data indicator
(orange) turn OFF.
Press and hold down the WRITE key for at least 2 seconds.
The WRITE indicator (orange) lights up.
Press the ENTER key within 5 seconds.
To cancel WRITE, press any key other than the ENTER key.
The WRITE indicator (orange) blinks and writing starts.
The control output (OSSD 1 / 2) of the light curtain turns OFF.
The WRITE indicator (orange) turns OFF.
The settings saved in the device are written to the light curtain.
Disconnect the connection cable of the device from the connector
inside the light curtain.
Description