installation

Venting

THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY
FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE.
This appliance is designed to be attached to two 3" (76 mm) co-linear
aluminium flex running the full length of the chimney. The flue length must
be a minimum length of 8' (2.43 m) and a maximum of 35' (10.67 m).
Periodically check that the vent is unrestricted.
Masonry chimneys may take various contours which the flexible liner will
accommodate. However, keep the flexible liner as straight as possible,
avoid unnecessary bending.
INSTALLATION WITH 3" (76 mm) & 3" (76 mm)
LINERS
Part #
Description
948-305
3" (76 mm) Flex - 35 ft. (10,67 m) (intake & exhaust)
946-529
Regency Co-linear DV Vertical Termination Cap & Flashing
Vent Restrictor
Vent Run
Position
8' to 20'
1" (25 mm)
20' to 35'
3/4" (19 mm)
NOTE: See instructions in the "Vent Restrictor Position"
section on positioning of the vent restrictor.
Alternative Approved Venting Components*
46DVA-VC Vertical Termination Cap
46DVA-VCH High Wind Cap
46DVA-GK 3" (76 mm) Co-linear Adaptor with flashing
In areas of consistently high winds, we recommend using the Simpson
Dura-Vent System 46DVA-GK adapter and 46DVA-VCH high-wind cap.
The Air Intake pipe must be attached to the inlet air collar of the termination
cap.
*NOTE: Simpson Duravent can only be used with 3" (76 mm) liners.
|
18
Liberty
L234-11 Direct Vent Gas Insert
®
Burner Aeration
Setting
3/16" (5 mm)
3/16" (5 mm)
The L234 is also approved for use with a 2" liner for air intake and a 3" liner
for exhaust. This would be suitable for a Class A wood burning chimney
with a minimum 6" round flue.
The chimney must be lined with one 2" diameter liner for intake and one 3"
diameter liner for exhaust. The minimum vent length is 8' and maximum is 35'.
INSTALLATION WITH 3" & 2" LINERS
Part #
Description
948-305
3" (76 mm) Flex - 35 ft. (10,67 m) (exhaust)
948-316
2" (51 mm) Flex - 35 ft. (10,67 m) (intake)
946-582
Regency Co-linear DV Ver tical Ter mination Cap,
Flashing & 2" (51 mm) Collar
Vent Restrictor
Vent Run
Position
8' to 20'
1" (25 mm)
20' to 35'
1" (25 mm)
NOTE: See instructions in the "Vent Restrictor Position"
section on positioning of the vent restrictor.
Burner Aeration
Setting
3/16" (5 mm)
1/8" (3 mm)