Maintenance Maintenance Instructions; General Vent Maintenance; Log Replacement; Glass Gasket - Regency Liberty L234 Series Owners & Installation Manual

Gas insert
Hide thumbs Also See for Liberty L234 Series:
Table of Contents

Advertisement

maintenance
Maintenance
Instructions
1) Always turn the gas valve to the off position
before cleaning. For relighting, refer to
lighting instructions. Keep the burner and
control compartment clean by brushing and
vacuuming at least once a year.
When cleaning the logs, use a clean soft
paint brush as the logs are fragile and easily
damaged.
2) Clean (never when unit is hot) appliance,
door and louvers with a damp cloth. Never
use an abrasive cleaner. The finishes on
louvers and doors may be scratched if
abrasives are used to clean them. The
heater is finished in a heat resistant paint
and should only be refinished with heat
resistant paint (not with wall paint). Regency
uses StoveBrite Paint - Metallic Black #6309.
3) Make a periodic check of the burner for
proper position and condition. Visually check
the flame of the burner periodically, making
sure the flames are steady: not lifting or
floating. If there is a problem, call a qualified
service person.
4) The appliance and venting system must be
inspected before use, and at least annually,
by a qualified field service person, to ensure
that the flow of combustion and ventilation
air is not obstructed.
During the annual service call, the burners
should be removed and cleaned from the
burner tray.
5) Keep the area near the appliance clear and
free from combustible materials, gasoline
and other flammable vapours and liquids.
WA R N I N G :
C H I L D R E N
ADULTS SHOULD BE ALERTED TO
THE HAZARDS OF HIGH SURFACE
TEMPERATURE AND SHOULD STAY
AWAY TO AVOID BURNS OR CLOTHING
IGNITION. YOUNG CHILDREN SHOULD
BE CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM AS
THE APPLIANCE.
CAUTION:
ANY SAFETY SCREEN
O R
G U A R D
R E M O V E D
SERVICING AN APPLIANCE MUST
BE REPLACED PRIOR TO OPERATING
THE APPLIANCE.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE.
6) Each time the appliance is lit, it may cause
condensation and fog the glass.
condensation and fog is normal and will
disappear in a few minutes as the glass heats
up.
|
36
Liberty
L234-11 Direct Vent Gas Insert
®
Never operate the appliance without the
glass properly secured in place or with
the door open.
7) Do not use this appliance if any part has
been under water. Immediately call a qualified
service technician to inspect the appliance
and to replace nay part of the control system
and any gas control which has been under
water.
8) Periodically check the pilot flames. Correct
flame pattern has three strong blue flames: 1
flowing around the thermopile and 1 around
the thermocouple, and 1 flowing across the
front of the burner.
Note: If you have an incorrect flame
pattern, contact your Regency
dealer for further instructions.
Front Burner Tube
Top view of pilot flame
Incorrect flame pattern will have small, probably
yellow flames, not coming into proper contact with
the rear of the burner or thermopile.
A N D
Front Burner Tube
Top View of pilot flame
General Vent
F O R
Maintenance
Conduct an inspection of the venting system
semi-annually. Recommended areas to inspect
as follows:
1) Check the Venting System for corrosion in
areas that are exposed to the elements. These
will appear as rust spots or streaks, and in
extreme cases, holes. These components
This
should be replaced immediately.
2) Remove the Termination Cap, and shine a
flashlight down the Vent. Remove any bird
nests, or other foreign material.
3) Check for evidences of excessive
condensation, such as water droplets forming
in the inner liner, and subsequently dripping
out the joints. Continuous condensation can
cause corrosion of caps, pipe, and fittings. It
may be caused by having excessive lateral
runs, too many elbows, and exterior portions
of the system being exposed to cold weather.
4) Inspect joints to verify that no pipe
sections or fittings have been disturbed,
and consequently loosened. Also check
mechanical supports such as Wall Straps,
or plumbers' tape for rigidity.

Log Replacement

The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door to carefully remove the
logs. The pilot light generates enough heat to
burn someone. If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagram under Log
Installation.
NOTE:
Improper positioning of logs may
create carbon build-up and will alter the unit's
performance which is not covered under
warranty.

Glass Gasket

If the glass gasket requires replacement use a
tadpole gasket for the Flush Front Glass (Part
# 936-155).

Door Glass

Your Regency insert is supplied with high
temperature, 5 mm Neoceram ceramic glass that
will withstand the highest heat that your unit will
produce. Do not abuse the glass by striking the
surface or by slamming the door shut.
If your glass requires cleaning, we recommend
using an approved glass cleaner available at
all authorized dealers. Do not use abrasive
materials. Do not clean the glass when hot.
In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency dealer only, do not use substitute
materials. Follow our step-by-step instructions
for replacement. Warning: Wear gloves when
removing damaged or broken glass.
Caution: Do not operate appliance with
glass panels removed, cracked or broken.
Replacement of the glass should be done
by a licensed or qualified service person.