Optional Wall
Thermostat
A wall thermostat may be installed if desired,
follow the wiring diagram below. Note: the wires
are connected to the "TH" on the gas valve. Use
the table below to determine the maximum wire
length. Regency offers an optional programmable
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.
It is recommended that the thermostat be
installed on an interior wall.
CAUTION
Do not connect the millivolt
wall thermostat wires
to the 120V wires.
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.

Final Check

Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly. This includes:
1) Clocking the appliance to ensure the correct
firing rate (noted on label) at 15 minutes.
2) If required, adjusting the primary air to ensure
that the flame does not carbon. First allow
the unit to burn for 15 min. to stabilize.
3) Check for proper draft.
Any alteration to the product that
causes sooting or carboning that
results in damage to the exterior
facia is not the responsibility of
50 Ft.
32 Ft.
20 Ft.
12 Ft.
9 Ft.
CAUTION
the manufacturer.
installation
DC Spark Igniter
Battery Installation
Install the supplied battery into the DC Sparker Box
by opening the battery compartment.
NOTE: The battery in the DC Sparker Box will
need to be replaced annually.
Liberty
L234-11 Direct Vent Gas Insert
®
|