Turn The System On With No Exit Tone (Delay Silent) - Bosch D623 User Manual

Hide thumbs Also See for D623:
Table of Contents

Advertisement

Security System
User Guide

Turn the System On with No Exit Tone (Delay Silent)

Use this command to turn the entire system All On, Part On, or Part 2 On without any exit tones. Remember that turning
the system on with no exit tone eliminates the tone emitted by the command center intended to alert occupants that the
system is about to arm.
This command is useful when you wish to arm the system, but not disturb the occupants while the system counts down
prior to arming.
1.
Make sure all points are normal (not faulted).
2.
Press and hold the appropriate key to silence the exit tone. The command center may prompt you to enter a
valid passcode.
Silencing the Exit Delay Tone doubles the Exit Delay period.
IMPORTANT
3.
Enter your passcode if necessary. The command center display shows the following for turning the system All
On:
If all points are normal, the display shows the following for Part On or Part 2 On. If the system is turned Part
2 On, the second line of the display shows Part 2 On:
4.
To turn the system on (All On, Part On, or Part 2 On) with no delay, press [NO DELAY]. See Turn the System
On with No Delay on page 14 for more information.
46841D
Arming With
To Silence Exit Tone
All On
Press and hold [ALL ON]
OR
Press [CMD], then press and hold [1].
Part On
Press and hold [PART ON]
OR
Press [CMD], then press and hold [2].
Part 2 On
Press [CMD], then press and hold [3].
120 seconds to
All On.
To bypass points
press Bypass.
For no delay
Press No Delay.
120 seconds to
Part On.
To bypass points
press Bypass.
For no delay
Press No Delay.
D623/D625 User Guide
Page 16
© 2003 Bosch Security Systems

Advertisement

Table of Contents
loading

This manual is also suitable for:

D625

Table of Contents