Siemens SINUMERIK 840D sl Function Manual page 707

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

8.7
Marginal conditions
The function "Axial Measurement" is not contained in the export versions SINUMERIK
840DE/840DiE.
8.8
Examples
8.8.1
Measuring mode 1
Measurement with one encoder
● One-time measurement
● One probe
● Trigger signals are the rising and falling edges
● Actual value from the current encoder
N2
N3
N4
N5
N6
N7
Measurement with two encoders
● One-time measurement
● One probe
● Trigger signals are the rising and falling edges
● Current values with two encoders
N2
N3
N4
N5
N6
N7
N8
N9
Extended Functions
Function Manual, 03/2009, 6FC5397-1BP10-4BA0
MEASA[X] = (1, 1, -1) G01 X100 F100
STOPRE
IF $AC_MEA[1]==FALSE gotof ENDE
R10=$AA_MM1[X]
R11=$AA_MM2[X]
END:
MEASA[X] = (31, 1, -1) G01 X100 F100
STOPRE
IF $AC_MEA[1]==FALSE gotof ENDE
R10=$AA_MM1[X]
R11=$AA_MM2[X]
R12=$AA_MM3[X]
R13=$AA_MM4[X]
END:
Measurement (M5)