9.2

Electrical, EMC and climatic requirements

Table 9-1
Product safety
Requirement
Safety regulations
Protection class
IP degree of protection
Electrical isolation stability
Use in hazardous areas
Electromagnetic compatibility
Analog input module AI 2xSG 4-/6-wire HS (7MH4134-6LB00-0DA0)
Manual, 09/2018, A5E41867508A-AB
Standards
IEC 61010-1:2010
+C1:2011 + C2:2013
IEC 61010-2-201:2014
UL 61010-1:2005
UL 61010-201:2014
IEC 61131-2:2007
CSA C22.2 No.142-M1987 (R2014)
IEC 60664:2007
IEC 61140:2016
IEC 61131-2:2007
DIN IEC 60529:2010 +A1:2000
+ A2:2013
IEC 61131-2:2007
CSA C22.2 No.142-M1987 (R2014)
IEC 60079-0 :2009
IEC 60079-7 :2015
IEC 61000-6-2 :2004
IEC 61000-6-4 :2007+ A1:2011
Technical specifications
9.2 Electrical, EMC and climatic requirements
Comments/measures
Overvoltage category II
Pollution degree 2
To maintain the safety characteristics of
extra-low voltage circuits, external con‐
nections to the analog circuits and the
24 V DC nominal power supplies must
be powered by approved sources that
fulfill the requirements according to the
various standards for SELV, PELV,
NEC Class 2, voltage limited or power
limited.
The ground connection for the DIN rail
serves as a functional ground for dissi‐
pating interference currents.
IP 20: Protection against contact with
standard probe
Protection against solid bodies with di‐
ameters in excess of 12.5 mm
No special protection against water
Between the chan‐
nels
Between the chan‐
nels and the back‐
plane bus
Between the chan‐
nels and the power
supply
See Product Information "Use of mod‐
ules in zone 2 hazardous areas"
(Product information
support.industry.siemens.com/cs/ww/
en/view/19692172)).
All shielded cables must be grounded at
both ends to comply with the require‐
ments for electromagnetic compatibility.
If the shielded cable is routed out of the
hazardous area for explosion-proof
equipment, both ends of the cable shield
must be connected to the potential
equalization.
No
707 V DC
(type test)
707 V DC
(type test)
(https://
49