Channel header information
The following tables show the structure of the header information channel.
Byte
2
Byte
3
Channel parameter block
The following tables show the structure of the channel parameter block. Enable a parameter
by setting the corresponding bit to "1".
More information on the parameters is available in the section Description of parameters
(Page 26).
Byte
4
5
Analog input module AI 2xSG 4-/6-wire HS (7MH4134-6LB00-0DA0)
Manual, 09/2018, A5E41867508A-AB
Bit
Number of the next channel parameter blocks = 2
0
0
1
1
2
0
3
0
4
0
5
0
6
0
7
0
Bit
Length of the next channel parameter block = 58
0
0
1
1
2
0
3
1
4
1
5
1
6
0
7
0
Bit
Name and meaning
0 ... 7
Reserved
0
Channel function
0: Channel deactivated
1: Channel activated
1
4/6-wire technology
0: 4-wire technology
1: 6-wire technology
2
Line frequency suppression
0: OFF
1: ON
3 ... 7
Reserved
Parameter data record