Table 4- 2 Cable Specifications To Comply With Emc Compatibility (Valid For Fsa To Fsc Only) - Siemens SINAMICS G120P Hardware Installation Manual

Power module pm230 ip55/ul type 12
Hide thumbs Also See for SINAMICS G120P:
Table of Contents

Advertisement

Connecting
4.3 Motor cable lengths and cross-sections
Table 4- 2
Cable specifications to comply with EMC compatibility (valid for FSA to FSC only)
PM230
Filter A
Filter B
* Power Modules with Class B integrated filters, frame sizes A to C, must be fitted with a ferrite ring on the motor cable
between the Power Module power terminals and the screening plate of the Power Module to fulfill EMI category C1
conditions. Use Class 1 75°C copper wire only (for UL compliance).
Power Modules with Class B integrated filters, frame sizes B and C must be fitted with a ferrite ring on the mains supply
input cable in addition to the ferrite ring on the motor cable.
The control cables must be laid separately from the power cables. The connection must be
carried out as shown in the installation section in this manual, to prevent inductive and
capacitive interference from affecting the correct function of the system.
Note
Ensure that the appropriate circuit-breakers or fuses with the specified current rating are
connected between the power supply and the inverter. The technical specifications contain
information about the circuit breaker and fuses. See Specifications.
EMC cable glands
To ensure compliance with the necessary EMC standards, it is recommended that all
communications and I/O cables from the Control Unit are fitted through the gland plate using
EMC compliant cable glands.
Radiated emission compliance
The PM230 Frame Sizes A to C inclusive, MUST use an EMC cable gland on the motor
cable to comply with radiated emissions standards.
40
Cable type
Screened
Screened
Unscreened
Screened
Screened
Unscreened
CAUTION
CAUTION
EMC category
C2
C3
None
C1 (conducted only)
C2
None
Hardware Installation Manual, 2010-07-02, A5E02923635A AB
Max. cable length
25 m (80 ft)
50 m (164 ft)
100 m (330 ft)
25 m (80 ft)*
50 m (164 ft)
100 m (330 ft)