Electrical-, Emc- And Climatic Requirements; Electrical Protection And Safety Requirements; Electromagnetic Compatibility - Siemens SIWAREX FTC Device Manual

Module for belt scale
Table of Contents

Advertisement

14.11 Electrical-, EMC- and Climatic Requirements

14.11.1 Electrical Protection and Safety Requirements

Requirement met
Safety regulations
Protection class
IP protection
Air and creepage distances
Isolation test
Fire and burn protection
Material
Table 14-11
Data: Electrical Protection and Safety Requirements

14.11.2 Electromagnetic Compatibility

interference emission (industrial use): EN 61000-6-4
Comments
Emission of radio interference
(electromagnetic fields)
Emission on power supply
lines
14-130 SIWAREX FTC
Standards
EN60204; DIN VDE 0113;
IEC 1131; UL 508;
CSA C22.2 No.142;
FM class I, Div.2;
UL/CSA
VDE 0106 Part 1
IEC 536
DIN 60529
IEC 529
IEC 1131
UL508
CSA C22.2 No.142
IEC 1131-2: 1992
CSA C22.2 No.142
for "Open Type Controller":
IEC 1131-2: 1992; UL 508
SN 36350 (3.93)
Standard
IEC 61131-2
IEC 61131-2
Comments
UL-/CSA-/FM Zone 2
certification upon request
Protection class I, with
protective conductor
in S7 frame: IP20
only SIWAREX FTC: IP10
Surge category II
Pollution degree 2
Circuit board material IIIa
Circuit track spacing 0.5 mm
Rated voltage 24 V
Test voltage 500 V DC
Limit values
EN 55011 Class A, Group 1
30 – 230 MHz: < 40dB(V/m) Q
230-1000MHz: < 47dB(V/m) Q
EN 55011 Class A, Group 1
EN 55014

Advertisement

Table of Contents
loading

Table of Contents