Mitsubishi Heavy Industries MHI FDU71VNXVF1 Technical Manual page 24

Inverter duct connected-high static pressure type air-conditioners
Hide thumbs Also See for MHI FDU71VNXVF1:
Table of Contents

Advertisement

POWER SOURCE 3N~380ー415V 50Hz
TB
RD
L1
L1o
L1i
WH
L2o
L2
L2i
F(8A)
BL
L3
L3i
L3o
BK
N
Ni
No
NOISE FILTER
CN1
PWB3
YE/GN
CN2-1
T12
GN
F(4A)
THo-P
THo-R2
THo-A
CNW
CNIP
CNB
TB
TO INDOOR UNIT
RD
(BK)
(Y)
(RD)
1
BK
[
]
2
CNW2
POWER WIRES
1
2
BL
3
(OR)
SIGNAL WIRE
3
DH
WH
CNF
Optional
52X1
52X3
WH
(BK)
52X6
52X2
LED1
BK
CNH
BK
(BR)
CNR
CNS
CNEEV1
(WH)
(RD)
(WH)
1
2
3
4
63H1
20S
CH
M
SM1
Power cable, indoor-outdoor connecting wires
MAX over current
Power cable size
Power cable length
Model
2
(A)
(mm )
100
16
125
18
3.5
140
19
The specifications shown in the above table are for units without heaters. For units with heaters, refer
to the installation instructions or the construction instructions of the indoor unit.
Switchgear of Circuit breaker capacity which is calculated from MAX. over current should be chosen
along the regulations in each country.
The cable specifications are based on the assumption that a metal or plastic conduit is used with no
more than three cables contained in a conduit and a voltage drop is 2%. For an installation falling
outside of these conditions, please follow the internal cabling regulations. Adapt it to the regulation
in effect in each country.
RD
WH
BL
BK
CT
RD
Va
R1
U
R2
THo-S
THo-D
THo-R1
52C
LPT
CNTH
CNM
CNPS
18V
(WH)
(GR)
(WH)
CNI 3
15V
CONTROL
PWB1
BL
CNI1
(WH)
RD
CNA1
1
2
3
4
1 2
3
4
BL
(WH)
LED2
SW1
SW3
SW5
RD
CNA2
CNEEV2
CNFAN1
CNFAN2
BL
(WH)
(RD)
(WH)
(WH)
6
1
2
3
4
6
1
4
5
6 7
1
4
5
6 7
M
M
M
SM2
FMo1
FMo2
Local setting switch SW3(Set up at shipment OFF)
indoor-outdoor
Earth wire size
SW3-1
wire size x number
(m)
(mm)
26
23
φ1.6mm x 3
φ1.6
SW3-2
21
SW3-3,4
1
3
52C
R5
2
4
INVERTER
C3
PWB2
AC1 AC2 AC3
GN
G
CNR
R5
DM
BK
(WH)
K
+4
-6
RD
CNW2
BL
(WH)
C4
L
RD
RD
RD
TB5
P
+
R3
C1
IPM
WH
+
R4
C2
BL
BL
TB6
N
RD
CNW1
BK
(WH)
CNI2
(WH)
RD
CNO1
BL
(RD)
The defrosting operation interval becomes shorter
by turning ON this switch. This switch should be
Defrost control change
turned ON in the area where outside temperature
becomes below the freezing point.
When this switch is turned ON, the outdoor unit
fan will run for 30 seconds in every 10 minutes,
when outdoor temperature falls to 3℃ or lower and
Snow guard fan control
the compressor is not runnning when the unit is used
in a very snowy country, set this switch to ON.
Method of trial operation
1
Trial operation can be performed by using SW3-3,4.
2
Compressor will be in the operation when SW3-3 is ON.
Trial operation
3
Cooling trial operation will be performed when SW3-4 is OFF,
and heating trial operation when SW3-4 is ON.
4
Be sure to turn OFF SW3-3 after the trial operation is finished.
Item
Description
CH
Crankcase heater
CM
Compressor motor
CnA~Z
Connector
CT
Current sensor
DH
Drain pan heater
DM
Diode module
F
Fuse
FMo1,2
Fan motor
IPM
Intelligent power module
L
Reactor
U
RD
U
LED1
Indication lamp(GREEN)
V
V
MS
WH
3~
W
W
BL
LED2
Indication lamp(RED)
CM
LPT
Low pressure sensor
SM1
Expansion valve for cooling
SM2
Expansion valve for heating
SW1
Pump down switch
SW3,5
Local setting switch
TB
Terminal block
THo-A
Thermistor(Outdoor air temp.)
THo-D
Thermistor(Discharger pipe temp.)
THo-R1,2
Thermistor(Heat exchanger pipe temp. )
THo-S
Thermistor(Suction pipe temp.)
THo-P
Thermistor(IPM)
20S
Solenoid valve for 4 way valve
52C
Relay
52X1
Auxilliary relay(for CH)
52X2
Auxilliary relay(for DH)
52X3
Auxilliary relay(for 20S)
52X6
Auxilliary relay(for 52C)
63H1
High pressure switch
Mark
Color
BK
Black
BL
Blue
BR
Brown
OR
Orange
RD
Red
WH
White
YE
Yellow
YE/GN
Yellow/Green
GR
Gray
P
Pink