Parker Gemini GT6 Series Hardware Installation Manual page 80

Digital stepper controller
Hide thumbs Also See for Gemini GT6 Series:
Table of Contents

Advertisement

RS-232/485 Connector – Configuration Port: see page 34
To configure all drive parameters, connect a PC or HPC to this
port. Use Motion Planner or Pocket Motion Planner for drive
configuration.
RS-485 Connections
RS-232 Connections
Rx+
Tx+
Gnd
(RD B)
(TD B)
Rx Tx
1
2
1
2
3
4
5
Male
6
7
8
9
6
Pins
Rx-
Tx-
(RD A)
(TD A)
+24VDC/Relay Connector – see page 32
+24VDC provides keep alive
power to drive
When drive is enabled, it
+24V DC
holds relay closed.
24V RTN
Relay rating: 5A at 24VDC or
RELAY COM
120VAC.
RELAY N.O.
If drive is faulted or disabled,
relay will open. (Typical use:
control of motor brake.)
Motor Output Connections – see page 13
Motor
Drive
Wires
Terminals
A+
A+
A–
A–
B+
B+
B–
B–
Earth
Motor Cable
Drive terminals: #8 (M4)
Mating terminals:
spade fork, 0.325"
maximum width.
AC Input Connections– see page 14
Fuses
Fuses
N/C
N
95 – 132VAC
95 – 132VAC
L1
GT6-L5/8
Drive terminals:
#8 (M4).
Mating terminals:
spade fork, 0.325" maximum width.
Protective Circuits – see page 58
Short Circuit Protection
Inrush Current Protection
Drive Overtemperature Protection
Undervoltage Protection
Regeneration Protection
Environmental Specifications – see page 49
Operating Temperature
Still Air:
45°C (113°F)
Moving Air: 50°C (122°F)
Minimum:
Storage Temperature:
-40°C – 85°C (-40°F – 185°F)
Humidity:
0 – 95%, non-condensing
Gnd
3
4
5
7
8
9
Connect jumper for
120VAC operations
V DBL
Fuses
L2/N
190 – 264VAC
L1
GT6-U5/8
0°C (32°F)
Gemini GT6
Digital Stepper
Controller/Drive
+24V DC
24V RTN
RELAY COM
RELAY N.O.
COMPUMOTOR
STEPPER
A+
A–
B+
B–
N/C
N
L1
GT-L5/8
V DBL
L2/N
L1
LEDs – see page 40
Green/Red
Yellow/Green
LED Color:
Left
Right
Indicated State
Off
Yel
Initialization
Red (flash) Off
Awaiting flash download
Grn (flash) Yel (flash)
Programming flash memory
Red
Grn
Keep alive mode
Grn
Grn (flash)
Incoming steps (variable rate)
Grn
Yel/Grn (flash)Autorun mode
Red
Off
Drive not enabled
Drive faulted
Grn
Off
Drive ready
50 Pin DRIVE I/O Connector – see page 50
Output Ground
50
25
25
Output 6
49
24
24
Output 5
48
23
23
Output Ground
47
22
22
Output 4
46
21
21
Output 3
45
20
20
Output Ground
44
19
19
Output 2
43
18
18
Output Ground
42
17
17
Output 1
41
16
16
Input Ground
40
15
15
Input 8
39
14
14
Input 7
38
13
13
Input 6
37
12
12
Input Ground
36
11
11
Input 5
35
10
10
Input 4
34
9
9
CNTRL-P: 4 – 8
33
8
8
Input Ground
32
7
7
Input 3
31
6
6
Input Ground
30
5
5
Input 2
29
4
4
Input 1
28
3
3
CNTRL-P: 1 – 3
27
2
2
VINref
26
1
1
Troubleshooting – see page 39
Commonly used status commands (binary status bits are
numbered 1 to n, from left to right):
TERRLG Error log reports the last 10 error conditions
(cleared with CERRLG).
TAS
General report, including fault conditions.
TASX
Additional report of conditions not covered with
TAS.
TCS
If TASX bit #7 or bit #28 is set, you can identify
the cause with TCS.
TINO
Bit #6 indicates status of Enable input ("1" = OK
to enable drive).
TIN
Status of digital inputs, including end-of-travel
inputs.
TOUT
Status of digital outputs.
You must configure all motor parameters. Be sure to follow
the drive configuration procedure (see Chapter 2 Installation ).
Any fault condition causes the drive to shut down.
The drive can not be enabled (DRIVE1) unless the Enable
input is grounded and the Reset input is not grounded.
Use one of three methods to reset the drive (all command
settings are remembered after reset):
Issue the RESET command.
Momentarily close the Reset input.
Cycle power to the drive.
Analog Ground
Reserved
Reserved
Analog Output B
Analog Output A
Digital Ground
Reserved
Reserved
Direction– Out
Direction+ Out
Step– Out
Step+ Out
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Digital Ground
Digital Ground
Reserved
Reserved
Reset
Digital Ground
Enable

Hide quick links: