120VAC Operations:
1.
2.
3.
Fuses
95 – 132VAC
Power Connections
GT6-U5 and GT6-U8 AC Power Connections
Connections are illustrated in the drawing above, on the right.
Do not operate GT6-U5/8 in the 132VAC – 190VAC range, or the drive will be
120VAC Operations:
1.
2.
3.
4.
240VAC Operations:
1.
2.
3.
4.
Applying Power
1.
2.
3.
Proceed to Configuring the Drive.
Connect power system's safety earth to drive's protective conductor terminal,
marked with the
symbol. Do not fuse the protective conductor terminal.
Connect 120VAC, 50/60 Hz, single phase power line to drive's L1 and N terminals.
Reinstall the clear plastic terminal cover after you make connections.
Fuses
N/C
N
95 – 132VAC
L1
GT6-L5/8
Drive terminals:
#8 (M4).
Mating terminals:
spade fork, 0.325" maximum width.
permanently damaged.
Connect power system's safety earth to drive's protective conductor terminal,
marked with the
symbol. Do not fuse the protective conductor terminal.
Connect a short jumper between V DBL and L2/N. Use insulated wire for the
jumper, 18 AWG (0.75 mm
Connect 120VAC, 50/60 Hz, single phase power to drive's L1 and L2/N terminals
Reinstall the clear plastic terminal cover after you make connections.
Connect power system's safety earth to drive's protective conductor terminal,
marked with the
symbol. Do not fuse the protective conductor terminal.
Verify there is no jumper between V DBL and L2/N.
Connect 240VAC, 50/60 Hz, single phase power to drive's L1 and L2/N terminals.
Reinstall the clear plastic terminal cover after you make connections.
Verify that the load is not connected to the motor, and that the motor is clamped
securely in place.
Verify that a cable is not attached to the DRIVE I/O connector.
Apply power to the drive. The LEDs should display the following states:
Left LED
Right LED
red
off
off
yellow
red
off
Connect jumper for
120VAC operations
V DBL
L2/N
L1
GT6-U5/8
CAUTION
2
) or thicker diameter; keep the wire as short as possible.
Indicated State
initial power applied
drive initializing
drive ready, not enabled
Chapter 2 – Installation
V DBL
Fuses
L2/N
190 – 264VAC
L1