6 DeviceNet Option Drive Parameters

6
DeviceNet Option Drive Parameters
Confirm proper setting of the all parameters in
communications.
No.
(Addr.
Name
Hex)
b1-01
Frequency Reference
(180)
Selection
<1>
b1-02
Run Command
(181)
Selection
<1>
Operation Selection
F6-01
after Communications
(3A2)
Error
External Fault
F6-02
Detection Conditions
(3A3)
(EF0)
Stopping Method for
F6-03
External Fault from
(3A4)
Communication
Option
Torque Reference/
Torque Limit
F6-06
Selection from
<3>
Communications
Option
F6-07
NetRef/ComRef
(3A8)
Selection Function
22
YASKAWA ELECTRIC TOBP C730600 43A YASKAWA AC Drive-Option Card DeviceNet Installation Manual
Table 8 Parameter Settings
Description
Selects the frequency reference input source
0: Digital Operator - Digital preset speed d1-01 to d1-17
1: Terminals - Analog input terminal A1 or A2
2: MEMOBUS/Modbus communications
3: Option PCB
4: Pulse Input (Terminal RP)
Selects the run command input source
0: Digital Operator - RUN and STOP keys
1: Digital input terminals S
2: MEMOBUS/Modbus communications
3: Option PCB
Determines drive response when a bUS error is detected
during communications with the DeviceNet Option
0: Ramp to Stop
1: Coast to Stop
2: Fast-Stop
3: Alarm Only
<2>
Sets the condition for external fault detection (EF0)
0: Always detected
1: Detected only during operation
Determines drive response for external fault input (EF0)
detection during DeviceNet communication
0: Ramp to Stop
1: Coast to Stop
2: Fast-Stop
3: Alarm Only
<2>
0: Torque reference / torque limit via network
communications are disabled.
1: Torque reference / torque limit via network
communications are enabled.
0: Multi-step speed reference disabled (F7 mode)
1: Multi-step speed reference allowed (V7 mode)
Table 8
before starting network
<4>
Values
Default: 1
Range: 0~4
(Set to 3 for DeviceNet
only)
Default: 1
Range: 0~3
(Set to 3 for DeviceNet
only)
Default: 1
Range: 0~3
Default: 0
Range: 0~1
Default: 1
Range: 0~3
0
Default: 0