6.3.4
Heat pump terminal measurements
There are two connectors, 6-pin heater and 3-pin motor.
Heater
1 – Ground
2 – Heater line / hot (L)
3 – Heater neutral (N)
4 – NTC 1
5 – NTC common
6 – NTC 2
702_58300000170749_ara_en_c
Motor
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary
information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
6.3.4.1 6-pin connector (heater / NTC's / pump ground)
The 6-pin connector on the side of the heat pump connects to the
heat pump heater, heater NTC's and ground.
To check the 1200 W heater, measure the resistance between
terminals 2 – 3. If the resistance = ∞, the heater has failed and
the heat pump must be replaced.
Heater resistance as follows:
2 – 3: ~ 8.9 Ω (@ 77 ºF)
NTC resistances as follows:
4 – 5: ~ 10 kΩ (@ 77 ºF)
5 – 6: ~ 10 kΩ (@ 77 ºF)
4 – 6: ~ 20 kΩ (@ 77 ºF)
6.3.4.2 3-pin connector (3-pole BLDC motor)
The 3-pin connector on the end of the heat pump connects to the
3-pole BLDC motor. The power module controls motor speed,
starting and stopping.
Motor resistances as follows:
1 – 2: ~ 15.2 Ω (@ 68 ºF)
2 – 3: ~ 15.2 Ω (@ 68 ºF)
3 – 1: ~ 15.2 Ω (@ 68 ºF)
Page 79 of 82