Bosch SHP65TL5UC Repair Instructions page 46

Hide thumbs Also See for SHP65TL5UC:
Table of Contents

Advertisement

a. Correct placement (below left)
b. Wrong placement (below right)
5.2.4
Base mounted power module (control)
Power modules are located in the base on the right side of
dishwashers, not behind fascia panels. So:
• Dishwashers must be pulled out to change controls.
• Dishwashers must be pulled out to measure voltages &
resistances (at the control).
702_58300000170749_ara_en_c
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary
information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
5.2.4.1
To remove base-mounted power modules
Tools needed: # 2 Phillips and flat blade screwdrivers
1. Disconnect & pull out dishwasher – section 5.1.5.1.
2. Unplug power supply cord from rear of power module
(below left).
3. Lift off tank fleece insulation from right side of dishwasher.
4. Lift off cover from power module (below right).
5. Two plastic base tabs hold the power module in place. To
remove power module, gently pry base tabs until they
clear module (below left) and lift the module up from the
base. If necessary, gently pry up the rear of the power
module (below right).