2.2.2
Electrical Installation
Turn power off at the fuse box. The dishwasher electrical supply
junction box and dedicated receptacle must in an accessible
cabinet adjacent to the dishwasher (i.e. do not mount the junction
box or install a receptacle behind the dishwasher).
You will need a 2-1/2" (63.5mm) round cutout through the cabinet
to pass the electrical, water and drain lines through. If the cutout
is made through wood, sand it smooth. If the opening is made
through metal, use the included protective grommet or other
approved method to protect wiring from damage. Use the four (4)
screws in the parts bag (or appropriate fasteners) to securely
mount the junction box so it can be easily accessed.
702_58300000170749_ara_en_c
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary
information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
2.2.2.1 Hard-wire connections to supplied junction box
Connect the electrical supply as follows:
• Make sure the household receptacle meets the electrical
supply requirements as well as national and local codes.
• First strip outer casing of electrical wire to expose 2" - 3"
(51 - 76 mm) of inner wires, then strip 3/8" - 1/2" (10 - 13
mm) insulation from each wire.
• Insert the electrical wire through the provided strain relief
in the junction box and tighten the nut to secure it.
Attach wires to terminal block: black – L (hot), white – N (neutral)
& green –
(ground). Unscrew terminal screws, but don't loosen
or remove them as they may become damaged. Insert wires into
terminals and tighten screws onto wires snugly, but don't
overtighten. Attach cover to junction box with the four (4) screws.
Page 6 of 82