Toro Pro Sneak 360 Operator's Manual page 28

Vibratory plow
Hide thumbs Also See for Pro Sneak 360:
Table of Contents

Advertisement

Changing the Transmission Oil
Service Interval: Every 1,000 hours/Yearly (whichever
comes first)
1. Park the machine on a level surface, lower any
attachments, and stop the engine.
2. Clean the area around the fill plug with a cleaning
solvent (Figure 33).
Figure 33
1. Fill plug
3. Remove the fill and drain plug.
4. Drain the transmission oil into a container.
5. Insert the drain plug.
6. Fill the transmission until the oil level is even with the
bottom of the fill plug hole.
Checking the Axle Oil Levels
Service Interval: Every 100 hours
1. Park the machine on a level surface, lower any
attachments, and stop the engine.
2. Remove the fill plug from one of the axle differentials
(Figure 34).
Figure 34
1. Fill plug
3. Check the oil level.
1
2
g022229
2. Drain plug
1
g026665
2. Drain plug
Note: The oil level should be even with the bottom
of the fill plug hole.
4. Add oil to raise the oil level up to the bottom of the
fill plug hole.
5. Install the fill plug.
6. Repeat for the other differential.
Changing the Axle Oil
1. Place a drain pan under the pinion housing of the axle.
2. Park the machine on a level surface, lower any
attachments, and stop the engine.
3. Remove the bolts securing the cover, and remove the
cover and gasket.
1
2
1. Cover
4. Clean the surfaces and install a new gasket.
5. Install the cover and drain plug.
6. Remove the fill plug.
7. Fill with differential oil until the oil is level with the
bottom of the fill plug hole.
8. Install the fill plug.
9. Repeat the procedure for the other differential.
28
g026668
Figure 35
2. Drain pan

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2540025400a25400c