2-2. Charging
If "Charging Complete Limited Due to Battery Temp" is
shown
Likely cause
Charging was stopped to protect the
hybrid battery (traction battery) as it
continued to remain hot for a certain
period of time.
If "Charging Stopped Check Charging Source" is shown (1)
Likely cause
Problem in power supply from exter-
nal power source
Correction procedure
Allow the hybrid battery (traction bat-
tery) to cool down and perform
charging again if the charging
amount has not reached the desired
amount.
Correction procedure
Check the following items.
 Plug is not disconnected
 Power source indicator on the
CCID (Charging Circuit Interrupting
Device) is illuminated
 The circuit breaker has tripped
If there is no problem with any of the
above items, there may be a prob-
lem with the outlet of the building.
Contact an electrician and request
an inspection. (Contact the facility
manager of the charging station
when there is a problem with
charging station.)
If charging cannot be carried out,
even though there is no problem with
the power source path, there may be
a malfunction in the system. Have
the vehicle inspected by your Toyota
dealer.
Furthermore, if the error warning
indicator on the CCID (Charging Cir-
cuit Interrupting Device) is flashing,
there may be an electrical leakage.
Consult your Toyota dealer.

Advertisement