Troubleshooting Steps
Troubleshooting Steps
Use a process of elimination to troubleshoot network problems.
Use a process of elimination to troubleshoot network problems.
1. If the LCD screen of the ICON gauge displays a value of zero (0) in any data field, it indicates the gauge is
1. If the LCD screen of the ICON gauge displays a value of zero (0) in any data field, it indicates the gauge is
not receiving a signal from one or more devices.
not receiving a signal from one or more devices.
• Make sure the data sources are configured.
• Make sure the data sources are configured.
• If multiple data fields are displaying "0", check common items such as cables and t-connectors.
• If multiple data fields are displaying "0", check common items such as cables and t-connectors.
• Remove components from the network one at a time to isolate failed components.
• Remove components from the network one at a time to isolate failed components.
• Look for damaged parts.
• Look for damaged parts.
• Check connectors for corrosion.
• Check connectors for corrosion.
• Swap known good components (sensor, cables or t-connectors) to isolate the faulty component.
• Swap known good components (sensor, cables or t-connectors) to isolate the faulty component.
• Reconnect the good component to the network and the remove the next one in line.
• Reconnect the good component to the network and the remove the next one in line.
• Continue this process for each device, cable or tee connector on the network until the faulty part is found.
• Continue this process for each device, cable or tee connector on the network until the faulty part is found.
NOTE: After a component is reconnected to the network, cycle the key switch OFF and back ON to reset the
NOTE: After a component is reconnected to the network, cycle the key switch OFF and back ON to reset the
gauge(s).