DP-CL18
8.6.
Color Registration Sensor
Before performing the following steps, unplug AC cord, then remove the 4 toner cartridges (cyan, magenta, yellow and black),
waste toner cartridge and accumulator unit from the printer
(1)
Open the right cover.
(2)
Open the PC holder assembly.
(3)
Remove the color registration sensor board assembly (1
screw).
(4)
Disconnect the color registration sensor cable.
(5)
Separate the color registration sensor board from the
registration sensor holder (2 screws).
(6)
If necessary, remove the accumulator unit detector and
detector spring from the registration sensor holder.
Note:
When replacing the color registration sensor board, perform the "Mis-Reg.Tbl Reset" (see the section 6.14 "Color Correction
Item Menu".) in the Service Mode to initialize the paprameter regarding the color registration.