8.10. IH (Inductive Heater) Unit

Before performing the following steps, remove all covers and fuser unit.
Caution: Handling of the IH Unit
When turning on the IH unit, the current (approx. 12 Arms: 100V AC Power) flows in the IH unit. For safety, observe the
following:
If not necessary, don't remove the plastic and metal covers from the IH unit.
Don't loosen or remove any component (nuts, screws, fasten terminals, etc.) from the IH coil unit.
The current (approx. 12 Arms: 100V AC Power) flows in the IH coil unit. The following nuts and screws connect the IH cable
to the IH coil & thermostat cable. The thermostat cables are connected to the thermostats by the screws or the fasten terminals.
For protection from smoke, fire and other hazards, don't loosen (or remove) any component (nuts, screws, fasten
terminals, etc.) on (from) the IH coil unit.