Installing a filler panel
If you plan to remove a module from the chassis without immediately
replacing it, you must install a filler panel in the slot.
To install a filler panel:
Step
1
2
3

Replacing a CPU module in a single-CPU chassis

You must have access to the Console port and the Ethernet Management
port. Use the following procedure to replace a CPU module.
Before you replace a CPU module, you must obtain the boot configuration file,
configuration file, and hidden password files. If the /flash is accessible on the faulty
CPU, copy the files from /flash to the pcmcia card. If the /flash is not accessible on
the faulty CPU, obtain the files from another source, which can be another network
device, such as a tftp or ftp server. Alternatively, the files can be rebuilt using the
Customer Spec Book or the configuration from the VRRP peer 8600 switch.
Step
Saving configuration files
1
2
Copyright © 2007, Nortel Networks
.
Replacing a CPU module in a single-CPU chassis 75
Pull the filler panel away from the slot.
Action
Locate the slot where you want to install the filler panel.
Insert the filler panel into the slot (8010co Chassis), or place the filler
panel over the slot (8003, 8006, or 8010 Chassis).
Tighten the 2 screws with a Phillips screwdriver.
Action
Using the console port, login to the CPU.
Save boot and runtime configuration files to flash memory. Enter
the following commands:
ERS-8606:6# save config
Save config to file /flash/config.cfg successful.
ERS-8606:6# save bootconfig
Nortel Ethernet Routing Switch 8600
Installing Ethernet Routing Switch 8600 Modules
NN46205-304 01.03 Standard
4.1 2 January 2007
—End—
—End—