Jump-Starting The Machine; Figure 83 - Toro Spray Master Series Operator's Manual

46in and 52in sprayer
Table of Contents

Advertisement

Figure 83

1. Flange locknut
2. Negative battery cable
3. Carriage bolt
3.
Slip back the insulator cover of the positive
battery cable
(Figure
4.
Remove the flange locknut and carriage bolt that
secure the positive battery cable to the battery,
and remove the cable from the battery
83).
5.
Remove the battery strap from the flange of the
battery box
(Figure
6.
Remove the battery from the battery box of the
machine.
Installing the Battery
1.
Place the battery into the battery box.
2.
Secure the battery to the battery box with the
battery strap
(Figure
3.
Assemble the positive battery cable to the
positive terminal of the battery with the carriage
bolt and flange locknut
4.
Slip back the insulator cover of the positive
battery cable over the battery terminal.
5.
Assemble the negative battery cable to the
positive terminal of the battery with the carriage
bolt and flange locknut
4. Positive battery cable
5. Battery strap
6. Strap flange (battery box)
83).
(Figure
83).
83).
(Figure
83).
(Figure
83).

Jump-Starting the Machine

DANGER
Jump-starting a battery that is cracked, frozen,
has low electrolyte level, or an open/shorted
battery cell can cause an explosion, resulting
in serious personal injury.
Do not jump-start a battery if these conditions
exist; replace the battery.
CAUTION
Corrosion or loose connections can cause
g313031
unwanted electrical voltage spikes at any time
during the jump-starting procedure.
Do not attempt to jump start a machine
with loose or corroded battery terminals, or
damage to the engine can occur.
CAUTION
Connecting the jumper cables incorrectly can
immediately damage the electrical system.
Be certain of the battery-terminal polarity and
the jumper-cable polarity when connecting to
the battery.
Important:
Be sure that the vehicles do not touch
and that both electrical systems are off and at the
same rated system voltage. These instructions
are for negative-ground systems only.
Important:
Use the properly sized jumper cables
(4 to 6 AWG) with short lengths to reduce the
voltage drop between systems. Ensure that the
cables are color coded or labeled for the correct
polarity.
1.
Check the battery terminals of the discharged
battery and the booster battery for corrosion
(white, green, or blue "snow").
Note:
Clean the corrosion from the battery
terminals prior to jump starting. Tighten the
battery cable connections as necessary.
2.
Ensure that the booster is a 12 V battery with
a sufficient amp rating that is in good condition
and fully charged.
Note:
Ensure that the vent caps are tight and
level. If available, place a damp cloth over any
vent caps on both batteries.
3.
Connect the positive (+) cable clamp (red) to the
positive (+) terminal of the discharged battery
(Figure
84).