Prepare The Machine For Maintenance; Refer To Preparing The Machine; Figure 81 - Toro Spray Master Series Operator's Manual

46in and 52in sprayer
Table of Contents

Advertisement

Checking the Battery Charge
CAUTION
If the ignition is in the O
is potential for sparks and for engine
components to move. Sparks could cause an
explosion or moving parts could accidentally
engage, causing personal injury.
Ensure that the ignition switch is in the O
position before charging the battery.
1.
Prepare the machine for maintenance; refer to
Preparing the Machine (page
2.
Carefully slip back the insulator cover of the
positive battery cable

Figure 81

1. Negative battery terminal
3.
Measure the voltage of the battery with a
voltmeter.
4.
Use the table below to locate the charge state
or the battery, and if needed, the battery-charger
setting and charging interval recommended to
charge the battery to 12.6 V or greater; refer to
the battery charge table below.
Important:
Ensure that the negative battery
cable is disconnected, and the battery
charger used for charging the battery
has an output of 16 V and 7 A or less to
avoid damaging the battery (see chart for
recommended charger settings).
position, there
N
FF
51).
(Figure
84).
g313000
2. Positive battery terminal
Battery Charge Table
Voltage
Percent
Reading
Charge
12.6 or
100%
greater
12.4 to 12.6
75 to 100%
12.2 to 12.4
50 to 75%
12.0 to 12.2
25 to 50%
11.7 to 12.0
0 to 25%
11.7 or less
0%
5.
If the positive cable is also disconnected,
connect the positive (red) cable to the positive
battery terminal and slip terminal cover over the
positive terminal
6.
Remove the screw, washer, and ground cable
from the engine. Secure the battery cable to
the battery terminal with the bolt, washer, and
nut and torque the nut and bolt to 1978 to 2542
N∙cm (175 to 225 in-lb).
Note:
If time does not permit charging the
battery or if charging equipment is not available,
connect the negative battery cables and run
the vehicle continuously for 20 to 30 minutes to
charge the battery.
7.
Carefully slip back the insulator cover of the
positive battery cable over the battery terminal
(Figure
81).
60
Maximum
Charging
Charger
Interval
Settings
16 V/
No Charging
7 A
Required
30 Minutes
16 V/
7 A
16 V/
1 Hour
7 A
2 Hours
14.4 V/
4 A
14.4 V/
3 Hours
4 A
14.4 V/
6 Hours or
2 A
More
(Figure
81).

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spray master 34233Spray master 34235Spray master 34237Spray master3423334235 ... Show all