6G-2. Home Position Adjustment [FT3020]
NOTE: * After adjusting the horizontal magnifica-
tion do this adjustment.
* Turn the main switch off before doing
home position adjustment.
1.
Move the scanner bracket 24.5mm (0.96")
from the outside of the left optical frame.
2.
Uncouple the home position switch connector.
3.
Connect the multimeter lead clips to the home
position switch and select OHM range.
4.
Move the home position switch bracket from
the right to the left just to the point where the
5.
Secure the home position switch bracket.
6-63