OPTICS
2.4 LENS AND 4TH/5TH MIRROR POSITION ADJUSTMENT
(A184 model only)
1. Remove the exterior covers and the exposure glass. (See Exterior
Cover/Exposure Glass Removal.)
2. Remove the lens cover [A] (1 screw).
3. Insert the two positioning pins [B]. If the pins cannot be inserted, loosen
the screw [C] and adjust the lens unit position.
NOTE: 1) Use the timing belt [D] to move the lens unit.
2) Scanner positioning pins are available as a service part.
P/N: A184 9501 (See the parts catalog.)
A183/A184
[A]
A184R547.wmf
[C]
6-8
[B]
[D]
A184R509.wmf
SM