July 1, '85
6G-5. Horizontal Magnification Adjustment
[FT3050/FT3060]
1.
Remove the rear cover (2 screws).
2.
Remove the top cover (8 screws).
3.
Loosen the wire clamp screws.
4.
Move the lamp right to enlarge the copy
image. Move it left to make the image
smaller.
(as viewed from the rear side)
5.
Tighten the wire clamp screw and check the
horizontal magnification in full size mode.
NOTE: This adjustment only effects horizontal
magnification.
controlled by the scanner speed.
6-66
Vertical magnification is