Technical Characteristics And Ambient Conditions; Directives And Standards - Siemens SIMOTICS S-1FK2 Operating Instructions Manual

Hide thumbs Also See for SIMOTICS S-1FK2:
Table of Contents

Advertisement

Description of the motors

2.2 Technical characteristics and ambient conditions

2.2
Technical characteristics and ambient conditions
2.2.1

Directives and standards

Standards that are complied with
Note
The standards listed in this manual are not dated.
You can take the currently relevant and valid dates from the Declaration of Conformity.
The motors of the type series SIMOTICS S, SIMOTICS M, SIMOTICS L, SIMOTICS T, SIMOTICS A,
called "SIMOTICS motor series" below, fulfill the requirements of the following directives and
standards:
• EN 60034‑1 - Rotating electrical machines – Dimensioning and operating behavior
• EN 60204‑1 - Safety of machinery – Electrical equipment of machines; general requirements
Where applicable, the SIMOTICS motor series are in conformance with the following parts of
EN 60034:
Feature
Degree of protection
Cooling
Type of construction
Connection designations
Noise levels
Temperature monitoring
Vibration severity grades
Standard component, e.g. cannot be applied to built-in motors
1)
Relevant directives
The following directives are relevant for SIMOTICS motors.
European Low-Voltage Directive
SIMOTICS motors comply with the Low-Voltage Directive 2014/35/EU.
European Machinery Directive
SIMOTICS motors do not fall within the scope covered by the Machinery Directive.
However, the use of the products in a typical machine application has been fully assessed for
compliance with the main regulations in this directive concerning health and safety.
20
1)
1)
1)
Standard
EN 60034‑5
EN 60034‑6
EN 60034‑7
EN 60034‑8
EN 60034‑9
EN 60034‑11
EN 60034‑14
SIMOTICS S-1FK2 synchronous motors for SINAMICS S120
Operating Instructions, 02/2022, A5E46089564B AD