Bypass Table - Minolta EP5000 Disassembly And Reassembly

Hide thumbs Also See for EP5000:
Table of Contents

Advertisement

(8) Adjustment of Reference Position of the Multi Bypass Table
z Requirement
Dimension A
1134D196AB
z Important
This adjustment should be made after the "adjustment of zoom ratio in the crosswise direction".
1136D030AA
1136D031AA
1156D099AA
D Dimension A on the copy of the GTC-test chart should mea-
sure 20 mm
2.0 mm in the full size (⋅ 1.000) mode.
1.
Place the GTC-test chart face down on the Original Glass
and align its rear left corner with the reference marker on
the Original Width Scale. Then, lower the Original Cover.
2.
Make three copies in the full size (⋅ 1.000) mode using A3
or 11" ⋅ 17" paper fed from the Multi Bypass Table.
3.
Check if dimension A (from the edge up to the reference
line) on the copy is up to the specifications. (Make the
check with the third copy.)
4.
If dimension A deviates from the specifications, loosen
three screws that secure the Multi Bypass Table and move
the table in the direction of the arrow as necessary.
Adjusting Instructions
D If dimension A on the copy is shorter than 18 mm, move
the table to the front of the copier.
D If dimension A on the copy is longer than 22 mm, move
the table to the rear of the copier.
NOTE
When tightening the screws, hold the Multi Bypass Table
from the underside with your hand and tighten screws in the
order shown.
When a Duplexing Document Feeder is mounted, it
involves changing the Original Glass. This in turn results
in the position of the Original Length Scale being
slightly shifted to the rear. This can nonetheless be
corrected with the Original Positioning Plate.
D-79

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ep4000

Table of Contents