1136D172AA
1136D173AA
1156D061AA
Coupling Holder
Collar
1134D047AA
9.
Remove two screws and the Cleaning Blade.
NOTE
When reinstalling the Cleaning Blade, press the blade
tightly up against the mounting bracket.
10. Unplug one connector.
11. Remove three screws and the PC Drum Paper Separator
Finger Holder Assy.
NOTE
When reinstalling the PC Drum Paper Separator Finger
Holder Assy, fit the collar of the assy onto the coupling
holder in the rear.