2-4. OPTICAL SECTION

(1) Cleaning of the Original Glass
1136D120AA
(2) Cleaning of the Scanner Shaft
1136D121AA
1156D040AA
(3) Cleaning of the Scanner Rail
1156D041AA
Wipe clean the Original Glass with a soft cloth.
NOTE
The surface of the Original Glass is coated with conductive
material. Do not use a wax-based detergent.
An alcohol-dampened cloth may be used if the glass is se-
riously contaminated.
1.
Remove the Original Width Scale.
2.
Remove the Original Glass.
3.
Wipe clean the Scanner Shaft (in the rear of the copier)
with a soft cloth.
NOTE
Apply a lubricating oil after cleaning the Scanner Shaft.
Wipe clean the Scanner Rail (at the front of the copier) with
a soft cloth.
NOTE
Apply a lubricating oil after cleaning the Scanner Rail.