10 Drive Commissioning (SIMODRIVE)
10.1 SIMODRIVE 611 universal/E, POSMO CD/CA and SI
Dialog box
10.1.7

Starting online operation

Start search
Display of the
drives
10-282
S
Open the hardware configuration of the station (double–click with left mouse
button on: Hardware; "HW Config" will be started)
S
Open DP master (in the example project: DP master) (double–click with left
mouse button on DP master)
S
You will find the subnet ID as follows using the Properties dialog box of the
DP master:
Dialog box: Properties – DP Master
Tab card: General
Group box: Interface
Type: PROFIBUS
Address: 2
Button: "Properties..."
Dialog box: Properties – PROFIBUS DP Master interface
Tab card: Parameter
Subnet: PROFIBUS
Button: "Properties..."
Dialog box: Properties PROFIBUS
Tab card: General
S7 subnet ID: 0010
Cancel
Cancel
Cancel
The online operation with the drives connected to PROFIBUS can now be
started.
After parameterization of the MPI interface and entry of the routing information,
SimoCom U can enter online operation with the SIMODRIVE drives.
To start the search for any drives connected,
– quit the above dialog box for setting the MPI interface with button:
"Go online"
or
– use menu command Commission > Search for online drives
The SIMODRIVE drives with which SimoCom U could start the online operation
are displayed in the SimoCom U main screen:
– Drive and dialog browser (left window)
– Status overview (upper status bar)
0005