Dp Slave: Diagnostic Repeater For Profibus Dp - Siemens SINUMERIK 840DiE sl Manual

Hide thumbs Also See for SINUMERIK 840DiE sl:
Table of Contents

Advertisement

8 PROFIBUS DP Communication

8.11 DP slave: Diagnostic repeater for PROFIBUS DP

8.11
DP slave: Diagnostic repeater for PROFIBUS DP
8.11.1
Function
SINUMERIK 840Di sl
DP Master
Diagnostics
Slave distance
DP Slave 611U
ADI4 DP slave
Segment 2
Fig. 8-24
Example: PROFIBUS topology with diagnostic repeater
8-238
Segment 1
DP slave
POSMO A
A diagnostic repeater can monitor the segment of an
RS 485 PROFIBUS subnet (copper cable) during normal operation and report
line faults in a diagnostic message frame to the DP master. Used together with
the SINUMERIK 840Di sl it is possible to display the location and cause of the
fault in plaintext.
The diagnostic repeater primarily performs the following tasks:
S
Diagnostic functions for two PROFIBUS segments (DP2 and DP3):
The diagnostic function supplies the location and causes of cable faults
such as wire breaks or missing terminating resistors.
S
Repeater functions for three PROFIBUS segments (DP1, DP2, DP3):
The diagnostic repeater amplifies the data signals on the bus cables and
connects up individual RS 485 segments.
S
Galvanic separation of the PG interface:
Galvanically or electrically isolating the PG interface prevents interference
with the other bus segments of the PROFIBUS DP if the PG connecting
cable is inserted or removed, even at high baud rates.
S
Monitoring functions of the clock–synchronous PROFIBUS
PG with SIMATIC STEP 7
Start:
Topology
determination
Diagnostic repeaters
Distance to
fault
DP–Slave ET200
Segment 3
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
01/2007
DP slave MCP 483