Lanier 5722 Operator's Manual page 98

Digital color printer/copier
Hide thumbs Also See for 5722:
Table of Contents

Advertisement

5
Press the TEST PRINT key to print out
the chart for calibration.
6
Press the CALIBRATION key after the
chart has been output.
7
When the display on the right appears, set
the chart face down on the glass and with
its top left aligned against the original
scale on the left side, in order that the black
line comes to the left side.
8
Press the START key to start the first
calibration.
● If the chart is not properly set, the following
message appears:
Set chart correctly
Repeat the calibration in Step 6.
Notes:
● If the glass is dirty or any foreign objects are
stuck to the glass, calibration may not be
operated properly. Keep the glass clean.
● Interrupt copying is not available during
calibration.