Error no.
Fault message displayed
710
• Vapour sensor defective
• Water pressure too low
• Water pressure too low
• No water in the siphon
• Unit restarted after power
failure
• WaveClean cancelled

6.3 Nameplate

Description
Steam elimination is now controlled
solely by the software. This results
in higher water consumption.
As continuous fault message
As sporadic fault message
The siphon is insufficiently filled
with water.
If there was no power failure in the
kitchen, an operating error may be
involved. For instance,
unintentionally switching on and off
while a cooking program was
running.
• Heed the explanations and instructions in the "Automatic cleaning
(WaveClean)" chapter
When contacting customer service, please always provide the following
data from the nameplate:
Serial number
(SN)
Type number
(TYP)
Operating instructions
Troubleshooting
Action
• Contact Customer service
• Open the water valve
• If water valve not closed, contact
customer service
• Activate fewer appliances simul-
taneously in the kitchen.
• Contact Customer service
• Open the water valve
• 2 l (0,53 gal) Pour water into the
cooking chamber
• If the fault message does not dis-
appear, contact customer service
• Power failure < 1 minute
• Confirm the power failure mes-
sage
• Continue the cooking program
• No cleaning necessary
• Power failure > 1 minute
• Cooking program cancelled
• Run the cleaning cycle