ICMP
About Default settings
The restore of factory setting is a feature that allows removing all settings performed on the ICMP and
replaces them with the default values set at the factory. Please refer to the Communicator user guide for
further information.
About the ICMP internal clock
The crystal on the ICMP board that manages the clock shows a certain drift (all crystals do). With the
Communicator the internal clock can be adjusted. This maintenance action should be repeated every 3
months. When neglected the system will locks up.
From ICMP software version 1.2.1 onwards it is possible to enable NTP (Network Time Protocol). You have to
configure (at installation) an IP address where the ICMP can find a sync signal. From then on, and as long as
the connection is active, the ICMP will automatically keep its clock correct. For detailed instructions see user
guide of the Communicator.

8.13 ICMP reset

This procedure requires that ICMP version 1.2.4 or later is installed.
ICMP reset possibilities
The Star button on the local keypad (Not for C- and B-series)
The ICMP reset button in the GUI of the Communicator.
The ICMP reset button in the GUI of the Commander.
The ICMP reset button in the GUI of the Web Commander.
The ICMP hardware reset button located on the front panel of the ICMP (Not recommended, use only
when all other reset possibilities are exhausted!)
How to reset the ICMP?
1.
Click on the ICMP reset button in the GUI of the Web Commander
or
Click on the ICMP reset button in the GUI of the Commander
Note: It can be that the Commander or WEB-Commander is not able to send the reset command.
or
click on the ICMP reset button in the GUI of the Communicator (recommended)
or
press the Star button on the local keypad for a few seconds (Not for C- and B-series)
As a result the projector is safely prepared for the ICMP reboot. All ongoing events on the ICMP (e.g. ingest)
are requested to end. After a few seconds the ICMP is requested to restart. The READY LED on the front
panel of the ICMP starts to blink orange.
In case the ICMP is installed in DP4K-L series projector the lasers are switched off and the projector remains
in the same mode (e.g. Conditioned). The Star button on the local keypad starts blinking green. After the reset
of the ICMP the lasers are switched on again.
Once the READY LED lit continuous green the ICMP is up and running.
2.
Did the reset of the ICMP fail?
► If yes,
perform a hardware reset as follows:
1.
switch off the lasers of the projector or switch of the projector lamp.
2.
press the ICMP hardware reset button a few seconds (reference 3 Image 8-13) .
Warning:
Resetting the ICMP with the hardware reset button may cause damage to the content on the
HDDs. A re-configuration of the whole system may be required!