Disconnect power for water pump.
Open the hot water tap in the bathroom
and kitchen.
Open safety/drain valve: Move the lever to
vertical position f.
The water heater is now drained directly to
the outside via the safety/drain valve. Check
that the water contents have been completely
drained (10 litres).
f
w
illing the
froSt control valve
Check if the rotary switch for the drain
valve is set to "Operation" (parallel to the
water connection) and engaged.
Close the drain valve by pushing the
button until it engages.
When the temperature at Frost control
is below about 7°C, first switch on
the heater to warm the installation
compartment and Frost control. After
several minutes, when the temperature at
Frost control is above 7°C the drain valve
can be closed.
Switch on power for water pump (main or
pump switch).
Open hot water taps in kitchen and
bathroom (set preselecting mixing taps or
single-lever fittings to "hot").
Leave the fittings open for as long as it
takes for the boiler to displace the air
and fill up and the water to flow without
interruption.
If just the cold water system is being operated
without using the water heater, the heater tank
also fills up with water. To avoid frost damage
the boiler must be drained through the drain
valve even if it was not operated.
When connecting to a central water supply
(rural or city mains) a pressure reduction valve
must always be installed to prevent above 2.8
bar from developing in the water heater.
d
raining the
froSt control valve
Switch off power to water pump (main or
pump switch).
Open hot water taps in kitchen and
bathroom.
In order to check the water that is flowing
out, place an appropriate container
h
(a
ater
eater
fter market
)
w
h
(a
ater
eater
fter market
)
(capacity 10 litres) beneath the drain valve
(Frost control) drainage muff.
Turn the rotary switch on the drain valve
by 180° until it engages, whereby the
push button moves out and the drain
valve opens.
Check whether all of the water in the
boiler (10 litres) has been drained into
the container via the drain valve.
There shall be no claims under guarantee for
damage caused by frost.
S
tart up
Heating is possible with gas, electrical and
mixed operation. Also with or without water.
Check to make sure the flue is
unobstructed. Be sure to remove any
covers that may be present.
Turn on gas cylinder and open quick-
acting valve in the gas supply line.
Check whether the power supply fuse
protection on the campsite is adequate
for the 900W (3.9A) or 1800W (7.8A)
that has been selected using the power
selector switch.
Fill boiler with water if necessary.
Switch on the unit on the control panel.
S
witching off
Switch the heater off on the control panel.
The switch-off procedure may be delayed
by several minutes because of internal
heater operations.
Always drain water contents if there is
a risk of frost.
If the appliance is not used for a long period,
close the quick acting valve in the gas supply
line and the gas cylinder.
m
aintenance
Only original Truma parts may be used for
maintenance and repair work.
Clean the compartment where the unit is
installed at least once annually.
Have an expert check the unit for dirt and
clean it if necessary.
The safety/drain valve must be operated
regularly (at least twice annually) to