Truma Combi 4E - Bailey ADVANCE 2019 Owner's Manual

Table of Contents

Advertisement

78
TRUMA COMBI E
1.
Control Panel
2.
Room Temperature Sensor
3.
Cold Water Connection
4.
Hot Water Connection
5.
Gas Connection
6.
Hot Air Outlets
7.
Recirculated Air Intake
8.
Waste Gas Discharge
9.
Combustion Air Feed
10.
Electronic Control Unit
11.
Water Container (10 litres)
12.
Burner
13.
Heat Exchanger
14.
Power Electronics
15.
Heating Elements 230V
16.
Overheating Switch 230c
17.
Frost control (Optional)
18.
Safety Drain Valve
f
d
unction
eScription
The liquid gas heater Combi E is a warm-air
heater with integrated hot water boiler (10
litres volume). The burner is fan assisted,
which ensures that operation is problem-free,
even when on the move. The unit also has
heating elements for electrical operation. In
heating and hot water mode the heater can
be used to heat the room and heat water up
at the same time. If only hot water is required,
select hot water mode. At a temperature
of approximately 3 °C at the automatic
FrostControl safety/drain valve, the valve will
open and drain the boiler.
3 different options are available for operating
the unit:
Gas mode only Propane / Butane for
autonomous use.
Electrical mode only 230 V for stationary
use on campsites
Gas and Electrical mode – mixed mode
only possible in winter.
Mixed operation is not possible. With
this setting the unit automatically
selects electrical operation. The gas
burner is not enabled.
Repairs may only be carried out by an
expert.
h
eating and hot water mode
In heating and hot water mode, the unit
automatically selects the required operating
level according to the temperature difference
between the temperature set on the control
panel and the current room temperature.
If the boiler has been filled, the water is
automatically heated as well. The water
temperature depends on the selected
operating mode and the heater output.
All 3 energy selection options can be used for
winter deployment.
In gas mode the unit automatically selects
the operating level that is required.
In electrical mode outputs of 900 W (3.9
A) or 1800 W (7.8 A) can be manually
preselected in accordance with the fuse
protection at the camp site.
If more output is required (e.g. heating up or
low outside temperatures) gas or mixed mode