Event Memory Recall Mode; Reset Panel/Clear Siren - Bosch AMAX panel 2000 Installation Manual

Hide thumbs Also See for AMAX panel 2000:
Table of Contents

Advertisement

AMAX panel 2000 / AMAX panel 2000 EN
4.
6.6

Event Memory Recall Mode

This function allows you to play back the last 254 system events that occurred. Event Memory
Recall Mode reports all alarms and each arming or disarming of the system and helps with
troubleshooting system faults. The events are shown using the keypad indicators.
Defined events are shown using keypad indicators, refer to Section 8.3 System Event Memory
Recall, page 69 for more information.
To enter Event Memory Recall Mode:
Enter your Code + [5] and press # two beeps sound.
Two beeps sound. The events are played back by the keypad indicators in reverse
chronological order.
Example
If the events occurred in the following order:
Sequence
1
2
3
4
Table 6.1 Event Sequence
The alarm memory is played back in this order:
Sequence
1
2
3
4
Table 6.2 Event Memory Playback
Sequnece indication Event
1.
2.
3.
4.
Each event is indicated by a beep and a lit indicator. Resetting a disarmed 24-Hour Alarm is
indicated by a beep only.
After the last event, two beeps sound to indicate the end of the playback. You can stop the
replay at any time by pressing [#] .
If the system is armed in STAY Mode, the STAY indicator shows the event memory playback.If
the control panel is powered down, the memory of all events is saved.
6.7

Reset panel/clear siren

This function allows code holders to reset all Alarms Faults and Tamper conditions.
Enter your code + [6] and press #.
Bosch Sicherheitssysteme GmbH
If the operation is not carried out within 240 seconds after entering the walk test mode,
the system will automatically exit from the setting.
Event
System armed in AWAY Mode
Alarm in Zone 3
Alarm in Zone 4
System disarmed
Indication
All indicators off
Zone 4 and away indicators light
Zone 3and away indicators light
AWAY indicator lights
All indicators off System disarmed
Zone 4 and AWAY indicators light Alarm in Zone 4
Zone 3 and AWAY indicators light Alarm in Zone 3
AWAY indicator lights System armed in AWAY Mode
Installation Manual
System Functions | en
Event
System disarmed
Alarm in Zone 4
Alarm in Zone 3
System armed in AWAY Mode
F.01U.241.127 | V4 | 2011.12
41