en | System Informations 2
2.
3.
2- Interior Instant
The interior instant zone will perform as below:
1.
2.
3.
3- Delay
The delay zone will perform as below:
1.
2.
3.
4- Interior Delay
The Interior delay zone will perform as below:
F.01U.241.127 | V4 | 2011.12
AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
(Zone triggered during exit time no Alarm / no report)
(Zone triggered during entry time Alarm / report is delayed for 30sec or entry time is
expired, when system is disarmed before, no report)
STAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
(Zone triggered during exit time no Alarm / no report)
(Zone triggered during entry time Alarm / report is delayed for 30sec or entry time is
expired, when system is disarmed before, no report)
When Zone is triggered, not bypassed and system is forced to arm, a Zone fault report is
sent.
When System is disarmed and zone is not restored before, a Zone fault restore report is
sent.
Disarm:
same as the Instant Zone disarm status
AWAY Arm:
same as the Instant Zone AWAY Arm status
STAY Arm:
This Zone will be Ignored and performed as disarm. Refer to Section Keypad Indicators,
page 20 to see how the zone is displayed during exit time.
When Zone is triggered, not bypassed and system is forced to arm, a Zone fault report is
send.
When System is disarmed and zone is not restored before, a Zone fault restore report is
sent
DISARM: Same as Instant zone disarm status
AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Entry time starts - no Alarm / no report
Disarming during entry time - no Alarm / no report
Zone triggered - during exit time - no Alarm / no report
Zone triggered - during entry time - no Alarm / no report
Zone triggered - entry time is expired - Alarm / report
(report is delayed for 30sec, when system is disarmed before, no report)
STAY ARM: Same as AWAY ARM performance.
First delay zone will start the entry time; all other delay zones will follow.
When System is disarmed and zone is not restored before, a Zone restore report is sent.